Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

ASHRAE Standard 15 Safety Standard for Refrigeration Systems (ANSI Approved), 2007
- FOREWORD
- 1. PURPOSE
- 2. SCOPE [Go to Page]
- 2.1
- 2.2
- 3. DEFINITIONS
- 4. OCCUPANCY CLASSIFICATION [Go to Page]
- 4.1
- 4.2
- 5. REFRIGERATING SYSTEM CLASSIFICATION [Go to Page]
- 5.1 Refrigerating Systems.
- 5.2 Refrigeration System Classification.
- 5.3 Changing Refrigerant.
- 6. REFRIGERANT SAFETY CLASSIFICATION [Go to Page]
- 6.1 Single-Compound Refrigerants.
- 6.2 Blends.
- 7. RESTRICTIONS ON REFRIGERANT USE [Go to Page]
- 7.1 General.
- 7.2 Refrigerant Quantity Limits.
- 7.3 Volume Calculations.
- 7.4 Location in a Machinery Room or Outdoors.
- 7.5 Additional Restrictions
- 8. INSTALLATION RESTRICTIONS [Go to Page]
- 8.1 Foundations.
- 8.2 Guards.
- 8.3 Safe Access.
- 8.4 Water Connections.
- 8.5 Electrical Safety.
- 8.6 Gas Fuel Equipment.
- 8.7 Air Duct Installation.
- 8.8 Refrigerant Parts in Air Duct.
- 8.9 Refrigerant Pipe Joint Inspection.
- 8.10 Location of Refrigerant Piping
- 8.11 Refrigerating Machinery Room, General Requirements.
- 8.12 Machinery Room, Special Requirements.
- 8.13 Manual Emergency Discharge of Ammonia Refrigerant. When required by the authority having jurisdiction, manual emergency dis...
- 8.14 Purge Discharge.
- 9. DESIGN AND CONSTRUCTION OF EQUIPMENT AND SYSTEMS [Go to Page]
- 9.1 Materials
- 9.2 System Design Pressure
- 9.3 Refrigerant-Containing Pressure Vessels
- 9.4 Pressure-Relief Protection
- 9.5 Setting of Pressure-Relief Devices
- 9.6 Marking of Relief Devices and Fusible Plugs
- 9.7 Pressure Vessel Protection
- 9.8 Positive Displacement Compressor Protection. When equipped with a stop valve in the discharge connection, every positive dis...
- 9.9 Pressure-Limiting Devices
- 9.10 Refrigerant Piping, Valves, Fittings, and Related Parts
- 9.11 Components Other Than Pressure Vessels and Piping
- 9.12 Service Provisions
- 9.13 Fabrication
- 9.14 Factory Tests
- 9.15 Nameplate.
- 10. OPERATION AND TESTING [Go to Page]
- 10.1 Field Tests
- 10.2 Declaration.
- 11. GENERAL REQUIREMENTS [Go to Page]
- 11.1 General Restrictions-Safeguards
- 11.2 Signs and Identification
- 11.3 Charging, Withdrawal, and Disposition of Refrigerants.
- 11.4 Containers.
- 11.5 Storing Refrigerant.
- 11.6 Maintenance.
- 11.7 Responsibility for Operation and Emergency Shutdown.
- 12. Precedence with Conflicting Requirements
- 13. Listed Equipment
- Informative APPENDIX A CALCULATIONS OF THE MAXIMUM ALLOWABLE CONCENTRATION (Cm) OF A BLEND [Go to Page]
- A1. FOR 100 LB OF BLEND, DETERMINE THE IDEAL GAS VOLUMES OCCUPIED BY EACH COMPONENT AND BY THE BLEND AT 70ËšF AND 1 ATM
- A2. Determine the dilution volume required for the 100 lb of blend and each component therein
- A3. Determine the maximum allowable concentration (Cm) of a blend
- Informative APPENDIX B GUIDELINES FOR EMERGENCY DISCHARGE OF REFRIGERANTS WHEN REQUIRED BY LOCAL CODES [Go to Page]
- B1. INTRODUCTION
- B2. Emergency Discharge Lines
- B3. Stop Valves
- B4. Sizing Valves and Lines
- B5. High- to Low-Pressure Valve
- B6. DIFFUSER
- B7. SIZING HEADERS AND DIFFUSERS
- B8. Location of Diffuser
- B9. Provide Drip Legs
- B10. Ammonia Diffusion Systems
- B11. Ammonia Discharge Lines
- B12. Ammonia Flares
- B13. Water Tanks
- B14. Basins
- B15. Ammonia-Water Mixers
- B16. Design Responsibility
- Normative APPENDIX C REFRIGERANT CLASSIFICATION SCHEME
- Informative APPENDIX D INFORMATIVE REFERENCES
- Normative APPENDIX E NORMATIVE REFERENCES
- Informative APPENDIX F METHOD FOR CALCULATING DISCHARGE CAPACITY OF POSITIVE DISPLACEMENT COMPRESSOR PRESSURE-RELIEF DEVICE
- Normative APPENDIX H ALLOWABLE EQUIVALENT LENGTH OF DISCHARGE PIPING
- Informative Appendix I Emergencies in Refrigerating Machinery Rooms [Go to Page]
- I1. Alarm Levels
- I2. Alternate Refrigerant Level Measurements
- I3. Reentry into Refrigerating Machinery Rooms
- I4. Example Emergency Procedures
- Informative appendix j addenda description information [Go to Page]