IEC 61347-2-7 Ed. 3.1 b:2017 Lamp controlgear - Part 2-7: Particular requirements for battery supplied electronic controlgear for emergency lighting (self-contained), 2017
- Redline version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 General notes on tests
- 6 Classification
- 7 Marking
- 8 Protection against accidental contact with live parts
- 9 Terminals
- 10 Provisions for protective earthing
- 11 Moisture resistance and insulation
- 12 Electric strength
- 13 Thermal endurance test for windings of ballasts controlgear
- 14 Fault conditions
- 15 Starting conditions
- 16 Lamp current
- 17 Supply current
- 18 Maximum current in any lead (with cathode preheating)
- 19 Lamp operating current waveforms
- 20 Functional safety (EBLF, EOFX)
- 21 Changeover operation
- 22 Recharging device
- 23 Protection against excessive discharge
- 24 Indicator
- 25 Remote control, rest mode, inhibition mode
- 26 Temperature cycling test and endurance test
- 27 Polarity reversal
- 28 Fault conditions
- 29 Construction
- 30 Creepage distances and clearances
- 31 Screws, current-carrying parts and connections
- 32 Resistance to heat, fire and tracking
- 33 Resistance to corrosion
- 34 Abnormal lamp conditions
- 35 Protection of associated components
- Annexes [Go to Page]
- Annex A (normative) Test to establish whether a conductive part is a live part, which may cause an electric shock
- Annex B (normative) Particular requirements for thermally protected lamp controlgear
- Annex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating
- Annex D (normative) Requirements for carrying out the heating test of thermally protected lamp controlgear
- Annex E (normative) Use of constant S other than 4 500 in tw tests
- Annex F (normative) Draught-proof enclosure
- Annex G (normative) Explanation of the derivation of the values of pulse voltages
- Annex H (normative) Tests
- Annex I (normative) Batteries for emergency lighting luminaires
- Annex J (informative) Rest mode and inhibition mode facilities
- Annex K (normative) Controlgear incorporating an automatic testing function for emergency lighting operation
- Annex L (informative) Compatibility between normal mains operation electronic controlgear and battery-powered emergency operation controlgear
- Bibliography
- Figures [Go to Page]
- Figure 1 – Suitable circuit for the measurement of lamp current and luminous flux
- Figure 2 – Circuit for testing rectifying effect
- Figure 3 – Circuit to test whether a controlgear can withstand a leaking burner
- Figure 4 – Circuit to test whether a controlgear can withstand rectification
- Figure L.1 – Timing diagram: changeover operation
- Figure L.2 – Supply voltage for the function test
- Tables [Go to Page]
- Table 1 – Voltage per cell to which the battery is discharged
- Table 2 – Relation between RMS working voltage and maximum peak voltage
- Table K.1 – Relevant requirements of IEC 62034
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l'Amendement 1
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Exigences générales
- 5 Généralités sur les essais
- 6 Classification
- 7 Marquage
- 8 Protection contre le contact accidentel avec des parties actives
- 9 Bornes
- 10 Dispositions en vue de la mise à la terre de protection
- 11 Résistance à l'humidité et isolement
- 12 Rigidité diélectrique
- 13 Essai d'endurance thermique des enroulements des ballasts appareillages
- 14 Conditions de défaut
- 15 Conditions de démarrage
- 16 Courant dans la lampe
- 17 Courant d’alimentation
- 18 Courant maximal en toute connexion (avec cathodes préchauffées)
- 19 Formes d'onde du courant fourni à la lampe
- 20 Sécurité fonctionnelle (EBLF, EOFX)
- 21 Opération de commutation
- 22 Dispositif de recharge
- 23 Protection contre les décharges excessives
- 24 Indicateur
- 25 Commande à distance, état de repos, état de neutralisation
- 26 Essai de cycles de températures et essai d'endurance
- 27 Inversion de polarité
- 28 Conditions de défaut
- 29 Construction
- 30 Lignes de fuite et distances dans l’air
- 31 Vis, parties transportant le courant et connexions
- 32 Résistance à la chaleur, au feu et aux courants de cheminement
- 33 Résistance à la corrosion
- 34 Conditions anormales des lampes
- 35 Protection des composants associés
- Annexes [Go to Page]
- Annexe A (normative) Essai ayant pour objet de déterminer si une partie conductrice est une partie active pouvant entraîner un choc électrique
- Annexe B (normative) Exigences particulières pour les appareillages de lampes à protection thermique
- Annexe C (normative) Exigences particulières pour les appareillages de lampes électroniques avec dispositifs de protection contre la surchauffe
- Annexe D (normative) Exigences pour l'essai d'échauffement des appareillages de lampes à protection thermique
- Annexe E (normative) Usage de constantes S différentes de 4 500 pour les essais tw
- Annexe F (normative) Enceinte à l’épreuve des courants d'air
- Annexe G (normative) Explications concernant le calcul des valeurs des impulsions de tension
- Annexe H (normative) Essais
- Annexe I (normative) Batteries pour luminaires d'éclairage de secours
- Annexe J (informative) Moyens de mise en état de repos et de neutralisation
- Annexe K (normative) Appareillage incorporant une fonction d’essai automatique pour le fonctionnement de l’éclairage de secours
- Annexe L (informative) Compatibilité entre l'appareillage électronique en fonctionnement normal par le réseau et l'appareillage en fonctionnement en mode secours alimenté par batterie
- Bibliographie
- Figures [Go to Page]
- Figure 1 – Circuit pour les mesures de courant fourni à la lampe et de flux lumineux
- Figure 2 – Circuit d’essai de l'effet redresseur
- Figure 3 – Circuit d’essai destiné à contrôler si un appareillage peut résister à une fuite du brûleur
- Figure 4 – Circuit d’essai en vue de contrôler si un ballast appareillage peut résister à un redressement
- Figure L.1 – Diagramme des temps: opération de commutation
- Figure L.2 – Tension d’alimentation relative à l'essai de fonction
- Tableaux [Go to Page]
- Tableau 1 – Tension par élément à laquelle est déchargée la batterie
- Tableau 2 – Relation entre la tension de service efficace et la tension de crête maximale
- Tableau K.1 – Exigences applicables de l’IEC 62034
- Final version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 General notes on tests
- 6 Classification
- 7 Marking
- 8 Protection against accidental contact with live parts
- 9 Terminals
- 10 Provisions for protective earthing
- 11 Moisture resistance and insulation
- 12 Electric strength
- 13 Thermal endurance test for windings of controlgear
- 14 Fault conditions
- 15 Starting conditions
- 16 Lamp current
- 17 Supply current
- 18 Maximum current in any lead (with cathode preheating)
- 19 Lamp operating current waveforms
- 20 Functional safety (EBLF, EOFX)
- 21 Changeover operation
- 22 Recharging device
- 23 Protection against excessive discharge
- 24 Indicator
- 25 Remote control, rest mode, inhibition mode
- 26 Temperature cycling test and endurance test
- 27 Polarity reversal
- 28 Fault conditions
- 29 Construction
- 30 Creepage distances and clearances
- 31 Screws, current-carrying parts and connections
- 32 Resistance to heat, fire and tracking
- 33 Resistance to corrosion
- 34 Abnormal lamp conditions
- 35 Protection of associated components
- Annexes [Go to Page]
- Annex A (normative) Test to establish whether a conductive part is a live part, which may cause an electric shock
- Annex B (normative) Particular requirements for thermally protected lamp controlgear
- Annex C (normative) Particular requirements for electronic lamp controlgear with means of protection against overheating
- Annex D (normative) Requirements for carrying out the heating test of thermally protected lamp controlgear
- Annex E (normative) Use of constant S other than 4 500 in tw tests
- Annex F (normative) Draught-proof enclosure
- Annex G (normative) Explanation of the derivation of the values of pulse voltages
- Annex H (normative) Tests
- Annex I (normative) Batteries for emergency lighting luminaires
- Annex J (informative) Rest mode and inhibition mode facilities
- Annex K (normative) Controlgear incorporating an automatic testing function for emergency lighting operation
- Annex L (informative) Compatibility between normal mains operation electronic controlgear and battery-powered emergency operation controlgear
- Bibliography
- Figures [Go to Page]
- Figure 1 – Suitable circuit for the measurement of lamp current and luminous flux
- Figure 2 – Circuit for testing rectifying effect
- Figure 3 – Circuit to test whether a controlgear can withstand a leaking burner
- Figure 4 – Circuit to test whether a controlgear can withstand rectification
- Figure L.1 – Timing diagram: changeover operation
- Figure L.2 – Supply voltage for the function test
- Tables [Go to Page]
- Table 1 – Voltage per cell to which the battery is discharged
- Table 2 – Relation between RMS working voltage and maximum peak voltage
- Table K.1 – Relevant requirements of IEC 62034
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l'Amendement 1
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Exigences générales
- 5 Généralités sur les essais
- 6 Classification
- 7 Marquage
- 8 Protection contre le contact accidentel avec des parties actives
- 9 Bornes
- 10 Dispositions en vue de la mise à la terre de protection
- 11 Résistance à l'humidité et isolement
- 12 Rigidité diélectrique
- 13 Essai d'endurance thermique des enroulements des appareillages
- 14 Conditions de défaut
- 15 Conditions de démarrage
- 16 Courant dans la lampe
- 17 Courant d’alimentation
- 18 Courant maximal en toute connexion (avec cathodes préchauffées)
- 19 Formes d'onde du courant fourni à la lampe
- 20 Sécurité fonctionnelle (EBLF, EOFX)
- 21 Opération de commutation
- 22 Dispositif de recharge
- 23 Protection contre les décharges excessives
- 24 Indicateur
- 25 Commande à distance, état de repos, état de neutralisation
- 26 Essai de cycles de températures et essai d'endurance
- 27 Inversion de polarité
- 28 Conditions de défaut
- 29 Construction
- 30 Lignes de fuite et distances dans l’air
- 31 Vis, parties transportant le courant et connexions
- 32 Résistance à la chaleur, au feu et aux courants de cheminement
- 33 Résistance à la corrosion
- 34 Conditions anormales des lampes
- 35 Protection des composants associés
- Annexes [Go to Page]
- Annexe A (normative) Essai ayant pour objet de déterminer si une partie conductrice est une partie active pouvant entraîner un choc électrique
- Annexe B (normative) Exigences particulières pour les appareillages de lampes à protection thermique
- Annexe C (normative) Exigences particulières pour les appareillages de lampes électroniques avec dispositifs de protection contre la surchauffe
- Annexe D (normative) Exigences pour l'essai d'échauffement des appareillages de lampes à protection thermique
- Annexe E (normative) Usage de constantes S différentes de 4 500 pour les essais tw
- Annexe F (normative) Enceinte à l’épreuve des courants d'air
- Annexe G (normative) Explications concernant le calcul des valeurs des impulsions de tension
- Annexe H (normative) Essais
- Annexe I (normative) Batteries pour luminaires d'éclairage de secours
- Annexe J (informative) Moyens de mise en état de repos et de neutralisation
- Annexe K (normative) Appareillage incorporant une fonction d’essai automatique pour le fonctionnement de l’éclairage de secours
- Annexe L (informative) Compatibilité entre l'appareillage électronique en fonctionnement normal par le réseau et l'appareillage en fonctionnement en mode secours alimenté par batterie
- Bibliographie
- Figures [Go to Page]
- Figure 1 – Circuit pour les mesures de courant fourni à la lampe et de flux lumineux
- Figure 2 – Circuit d’essai de l'effet redresseur
- Figure 3 – Circuit d’essai destiné à contrôler si un appareillage peut résister à une fuite du brûleur
- Figure 4 – Circuit d’essai en vue de contrôler si un appareillage peut résister à un redressement
- Figure L.1 – Diagramme des temps: opération de commutation
- Figure L.2 – Tension d’alimentation relative à l'essai de fonction
- Tableaux [Go to Page]
- Tableau 1 – Tension par élément à laquelle est déchargée la batterie
- Tableau 2 – Relation entre la tension de service efficace et la tension de crête maximale
- Tableau K.1 – Exigences applicables de l’IEC 62034 [Go to Page]