IEC 61391-1 Ed. 1.1 b:2017 Ultrasonics - Pulse-echo scanners - Part 1: Techniques for calibrating spatial measurement systems and measurement of point-spread function response, 2017
- Redline version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols and abbreviated terms
- 5 General conditions
- 6 Techniques for calibrating 2D-measurement systems [Go to Page]
- 6.1 Test methods
- 6.2 Instruments
- 6.3 Test settings
- 6.4 Test parameters
- 7 Methods for calibrating 3D-measurement systems [Go to Page]
- 7.1 General
- 7.2 Types of 3D-reconstruction methods
- 7.3 Test parameters associated with reconstruction problems
- 7.4 Test methods for measurement of 3D-reconstruction accuracy
- 8 Measurement of point-spread and line-spread functions (high-contrast spot size) [Go to Page]
- 8.1 General
- 8.2 Test methods
- 8.3 Instruments
- 8.4 Test settings
- 8.5 Test parameters
- Annex A (normative)Test objects – Calibration of 2D-spatial measurement systems
- Annex B (normative) Test objects – Measurement and calibration of 3D-image reconstruction accuracy
- Annex C (normative) Test objects – Measurement of point-spread function response
- Annex D (informative) Quality parameters derived by PSF-mapping analysis
- Bibliography
- Figures [Go to Page]
- Figure A.1 – Concentric circular arrays of nylon filaments
- Figure A.2 – Regular 2D-array of nylon filaments
- Figure B.1 – Tissue mimicking ovoid target phantom
- Figure B.2 – Composite of two cross-sectional views of test object shown in Figure B.1
- Figure B.3 – Projection view from top of test object shown in Figure B.1
- Figure B.4 – Projection view from end window of test object shown in Figure B.1
- Figure C.1 – Filament test object for measuring the LSF
- Figure C.2 – Axial resolution test object
- Figure C.3 – Movable single filament in water
- Figure C.5 – Slice thickness measurement and calculation
- Figure D.1 – Principal schematic of the PSF-analyser function
- Figure D.2 – Principle of elimination of internal multi-reflections in the spherical target using filtration in time domain
- Figure D.3 – A pixel maximum level and PSF-trace estimation in ROI stored digital data
- Figure D.4 – The derivation of FWHM-value from the lateral-amplitude profile of PSF received-echo signal (ar,max(xi,zk) = 221) with reflector positioned on axis of the ultrasound beam in point (xi,zk) of the measuring grid
- Figure D.5 – The FWHM-derivation from the elevational (transversal) profile of MER in one point of the measuring grid
- Figure D.6 – The derivation of the reflected-signal axial-profile from the ROI
- Figure D.7 – The enumeration of the WH,HM parameter from the axial-profile line: ar,max(x,z) = 243
- Figure D.8 – The distribution of FWHM over a scan area of width 20 mm to depth 80 mm, made with a monofocal scan using a linear 5 MHz transducer
- Figure D.9 – The distribution of FWHM over a scan area of width 20 mm to depth 80 mm, made with the same system as for Figure D.7 but using three focal points (F1, F2 and F3) for the scan
- Figure D.10 – Plot of the distribution of MER-intensity over the scanning area 30 mm wide and 40 mm deep
- Figure D.11 – The elevational profile recorded from ar,max(xi,y,zk) values for a spherical target passing perpendicularly to the scanning planein one point (xi,zk) of the measuring grid
- Tables [Go to Page]
- Table 1 – Expected values for the two ellipsoidal objects in Figure B.3
- Table 2 – Suggested table of reported values
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Symboles et termes abrégés
- 5 Conditions générales
- 6 Techniques d'étalonnage de systèmes de mesure 2D [Go to Page]
- 6.1 Méthodes d’essai
- 6.2 Instruments
- 6.3 Réglages d’essai
- 6.4 Paramètres d’essai
- 7 Méthodes d'étalonnage des systèmes de mesure 3D [Go to Page]
- 7.1 Généralités
- 7.2 Types de méthodes de reconstruction 3D
- 7.3 Paramètres d’essai associés aux problèmes de reconstruction
- 7.4 Méthodes d’essai pour la mesure de la précision de reconstruction 3D
- 8 Mesure des fonctions de dispersion ponctuelle et de dispersion linéaire (dimensions de la zone de résolution à haut contraste) [Go to Page]
- 8.1 Généralités
- 8.2 Méthodes d’essai
- 8.3 Instruments
- 8.4 Réglages d’essai
- 8.5 Paramètres d’essai
- Annexe A (normative) Objets d’essai – Étalonnage de systèmes de mesure spatiaux 2D
- Annexe B (normative) Objets d’essai – Mesure et étalonnage de la précision de reconstruction d’images 3D
- Annexe C (normative) Objets d’essai – Mesure de la réponse de la fonction de dispersion ponctuelle
- Annexe D (informative) Paramètres de qualité dérivés par analyse de la cartographie FDP
- Bibliographie
- Figures [Go to Page]
- Figure A.1 – Réseau circulaire concentrique de filaments en nylon
- Figure A.2 – Réseau 2D régulier de filaments en nylon
- Figure B.1 – Fantôme de cible ovoïde imitant le tissu
- Figure B.2 – Ensemble de 2 vues de coupe transversale de l’objet d’essai de la Figure B.1
- Figure B.3 – Vue en projection du dessus de l’objet d’essai de la Figure B.1
- Figure B.4 – Vue en projection de la fenêtre finale de l’objet d’essai de la Figure B.1
- Figure C.1 – Objet d'essai à filaments pour la mesure de la FDP
- Figure C.2 – Objet d’essai de résolution axiale
- Figure C.3 – Filament unique déplaçable dans l'eau
- Figure D.1 – Schéma de principe de la fonction d’analyseur FDP
- Figure D.2 – Principe d’élimination des multiréflexions internes dans la cible sphérique utilisant la filtration dans le domaine temporel
- Figure D.3 – Niveau maximal de pixel et estimation de la trace FDP dans les données numériques stockées dans une ROI
- Figure D.4 – Dérivation de la valeur FWHM d’après le profil d’amplitude latérale du signal d’écho reçu de la FDP (ar,max(xi,zk) = 221) en positionnant le réflecteursur l’axe du faisceau ultrasonique au point (xi,zk) de la grille de mesure
- Figure D.5 – Dérivation de la FWHM à partir du profil de profondeur (transversal) du MER au niveau d’un point de la grille de mesure
- Figure D.6 – Dérivation du profil axial du signal réfléchi à partir de la ROI
- Figure D.7 – Calcul du paramètre WH,HM à partir de la ligne de profil axial: ar,max(x,z) = 243
- Figure D.8 – Distribution de la FWHM sur une surface d’exploration de 20 mm de largeur sur 80 mm de profondeur, réalisée avec une exploration monofocale à l’aide d’un transducteur linéaire de 5 MHz
- Figure D.9 – Distribution de la FWHM sur une surface d'exploration de 20 mm de largeur sur 80 mm de profondeur, réalisée avec un système identique à celui de la Figure D.7 mais en utilisant trois points focaux (F1, F2 et F3) pour l'exploration
- Figure D.10 – Tracé de la distribution de l’intensité du MER sur la surface d'exploration de 30 mm de largeur et de 40 mm de profondeur
- Figure D.11 – Profil en hauteur enregistré à partir des valeurs ar,max(xi,y,zk) pour une cible sphérique traversant perpendiculairement le plan d’exploration en un point (xi,zk) de la grille de mesure
- Tableaux [Go to Page]
- Tableau 1 – Valeurs prévues pour les deux objets ellipsoïdaux de la Figure B.3
- Tableau 2 – Tableau suggéré de valeurs rapportées
- Final version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Symbols and abbreviated terms
- 5 General conditions
- 6 Techniques for calibrating 2D-measurement systems [Go to Page]
- 6.1 Test methods
- 6.2 Instruments
- 6.3 Test settings
- 6.4 Test parameters
- 7 Methods for calibrating 3D-measurement systems [Go to Page]
- 7.1 General
- 7.2 Types of 3D-reconstruction methods
- 7.3 Test parameters associated with reconstruction problems
- 7.4 Test methods for measurement of 3D-reconstruction accuracy
- 8 Measurement of point-spread and line-spread functions (high-contrast spot size) [Go to Page]
- 8.1 General
- 8.2 Test methods
- 8.3 Instruments
- 8.4 Test settings
- 8.5 Test parameters
- Annex A (normative) Test objects – Calibration of 2D-spatial measurement systems
- Annex B (normative) Test objects – Measurement and calibration of 3D-image reconstruction accuracy
- Annex C (normative) Test objects – Measurement of point-spread function response
- Annex D (informative) Quality parameters derived by PSF-mapping analysis
- Bibliography
- Figures [Go to Page]
- Figure A.1 – Concentric circular arrays of nylon filaments
- Figure A.2 – Regular 2D-array of nylon filaments
- Figure B.1 – Tissue mimicking ovoid target phantom
- Figure B.2 – Composite of two cross-sectional views of test object shown in Figure B.1
- Figure B.3 – Projection view from top of test object shown in Figure B.1
- Figure B.4 – Projection view from end window of test object shown in Figure B.1
- Figure C.1 – Filament test object for measuring the LSF
- Figure C.2 – Axial resolution test object
- Figure C.3 – Movable single filament in water
- Figure C.5 – Slice thickness measurement and calculation
- Figure D.1 – Principal schematic of the PSF-analyser function
- Figure D.2 – Principle of elimination of internal multi-reflections in the spherical target using filtration in time domain
- Figure D.3 – A pixel maximum level and PSF-trace estimation in ROI stored digital data
- Figure D.4 – The derivation of FWHM-value from the lateral-amplitude profile of PSF received-echo signal (ar,max(xi,zk) = 221) with reflector positioned on axis of the ultrasound beam in point (xi,zk) of the measuring grid
- Figure D.5 – The FWHM-derivation from the elevational (transversal) profile of MER in one point of the measuring grid
- Figure D.6 – The derivation of the reflected-signal axial-profile from the ROI
- Figure D.7 – The enumeration of the WH,HM parameter from the axial-profile line: ar,max(x,z) = 243
- Figure D.8 – The distribution of FWHM over a scan area of width 20 mm to depth 80 mm, made with a monofocal scan using a linear 5 MHz transducer
- Figure D.9 – The distribution of FWHM over a scan area of width 20 mm to depth 80 mm, made with the same system as for Figure D.7 but using three focal points (F1, F2 and F3) for the scan
- Figure D.10 – Plot of the distribution of MER-intensity over the scanning area 30 mm wide and 40 mm deep
- Figure D.11 – The elevational profile recorded from ar,max(xi,y,zk) values for a spherical target passing perpendicularly to the scanning plane in one point (xi,zk) of the measuring grid
- Tables [Go to Page]
- Table 1 – Expected values for the two ellipsoidal objects in Figure B.3
- Table 2 – Suggested table of reported values
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Symboles et termes abrégés
- 5 Conditions générales
- 6 Techniques d'étalonnage de systèmes de mesure 2D [Go to Page]
- 6.1 Méthodes d’essai
- 6.2 Instruments
- 6.3 Réglages d’essai
- 6.4 Paramètres d’essai
- 7 Méthodes d'étalonnage des systèmes de mesure 3D [Go to Page]
- 7.1 Généralités
- 7.2 Types de méthodes de reconstruction 3D
- 7.3 Paramètres d’essai associés aux problèmes de reconstruction
- 7.4 Méthodes d’essai pour la mesure de la précision de reconstruction 3D
- 8 Mesure des fonctions de dispersion ponctuelle et de dispersion linéaire (dimensions de la zone de résolution à haut contraste) [Go to Page]
- 8.1 Généralités
- 8.2 Méthodes d’essai
- 8.3 Instruments
- 8.4 Réglages d’essai
- 8.5 Paramètres d’essai
- Annexe A (normative) Objets d’essai – Étalonnage de systèmes de mesure spatiaux 2D
- Annexe B (normative) Objets d’essai – Mesure et étalonnage de la précision de reconstruction d’images 3D
- Annexe C (normative) Objets d’essai – Mesure de la réponse de la fonction de dispersion ponctuelle
- Annexe D (informative) Paramètres de qualité dérivés par analyse de la cartographie FDP
- Bibliographie
- Figures [Go to Page]
- Figure A.1 – Réseau circulaire concentrique de filaments en nylon
- Figure A.2 – Réseau 2D régulier de filaments en nylon
- Figure B.1 – Fantôme de cible ovoïde imitant le tissu
- Figure B.2 – Ensemble de 2 vues de coupe transversale de l’objet d’essai de la Figure B.1
- Figure B.3 – Vue en projection du dessus de l’objet d’essai de la Figure B.1
- Figure B.4 – Vue en projection de la fenêtre finale de l’objet d’essai de la Figure B.1
- Figure C.1 – Objet d'essai à filaments pour la mesure de la FDP
- Figure C.2 – Objet d’essai de résolution axiale
- Figure C.3 – Filament unique déplaçable dans l'eau
- Figure D.1 – Schéma de principe de la fonction d’analyseur FDP
- Figure D.2 – Principe d’élimination des multiréflexions internes dans la cible sphérique utilisant la filtration dans le domaine temporel
- Figure D.3 – Niveau maximal de pixel et estimation de la trace FDP dans les données numériques stockées dans une ROI
- Figure D.4 – Dérivation de la valeur FWHM d’après le profil d’amplitude latérale du signal d’écho reçu de la FDP (ar,max(xi,zk) = 221) en positionnant le réflecteur sur l’axe du faisceau ultrasonique au point (xi,zk) de la grille de mesure
- Figure D.5 – Dérivation de la FWHM à partir du profil de profondeur (transversal) du MER au niveau d’un point de la grille de mesure
- Figure D.6 – Dérivation du profil axial du signal réfléchi à partir de la ROI
- Figure D.7 – Calcul du paramètre WH,HMà partir de la ligne de profil axial: ar,max(x,z) = 243
- Figure D.8 – Distribution de la FWHM sur une surface d’exploration de 20 mm de largeur sur 80 mm de profondeur, réalisée avec une exploration monofocale à l’aide d’un transducteur linéaire de 5 MHz
- Figure D.9 – Distribution de la FWHM sur une surface d'exploration de 20 mm de largeur sur 80 mm de profondeur, réalisée avec un système identique à celui de la Figure D.7 mais en utilisant trois points focaux (F1, F2 et F3) pour l'exploration
- Figure D.10 – Tracé de la distribution de l’intensité du MER sur la surface d'exploration de 30 mm de largeur et de 40 mm de profondeur
- Figure D.11 – Profil en hauteur enregistré à partir des valeurs ar,max(xi,y,zk) pour une cible sphérique traversant perpendiculairement le plan d’exploration en un point (xi,zk) de la grille de mesure
- Tableaux [Go to Page]
- Tableau 1 – Valeurs prévues pour les deux objets ellipsoïdaux de la Figure B.3
- Tableau 2 – Tableau suggéré de valeurs rapportées [Go to Page]