IEC 61674 Ed. 3.0 b:2024 Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging, 2024
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope and object [Go to Page]
- 1.1 Scope
- 1.2 Object
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements [Go to Page]
- 4.1 Performance requirements
- 4.2 Reference values and standard test values
- 4.3 General test conditions [Go to Page]
- 4.3.1 Standard test conditions
- 4.3.2 Statistical fluctuations
- 4.3.3 Stabilization time
- 4.3.4 Adjustments during test
- 4.3.5 Batteries
- 4.4 Constructional requirements as related to performance [Go to Page]
- 4.4.1 Components
- 4.4.2 Display
- 4.4.3 Indication of battery condition
- 4.4.4 Indication of polarizing voltage failure
- 4.4.5 Over-ranging
- 4.4.6 Measuring assemblies with multiple detector assemblies
- 4.4.7 Radioactive stability check device
- 4.5 Uncertainty of measurement
- 5 Limits of performance characteristics [Go to Page]
- 5.1 Linearity
- 5.2 Repeatability [Go to Page]
- 5.2.1 General
- 5.2.2 Repeatability in the attenuated beam
- 5.2.3 Repeatability in the unattenuated beam
- 5.3 Resolution of reading
- 5.4 Stabilization time
- 5.5 Effect of pulsed radiation on air kerma and air kerma length product measurements
- 5.6 Stability [Go to Page]
- 5.6.1 Long term stability
- 5.6.2 Accumulated dose stability
- 5.7 Measurements with a radioactive stability check device
- 6 Limits of variation for effects of influence quantities [Go to Page]
- 6.1 General
- 6.2 Energy dependence of response
- 6.3 Air kerma rate dependence of air kerma and air kerma length product measurements
- 6.4 Dependence of detector response on angle of incidence of radiation [Go to Page]
- 6.4.1 Non-CT detectors
- 6.4.2 CT detectors
- 6.5 Operating voltage [Go to Page]
- 6.5.1 Mains-operated dosimeters
- 6.5.2 Battery-operated dosimeters
- 6.5.3 Mains rechargeable, battery-operated dosimeters
- 6.6 Air pressure
- 6.7 Air pressure equilibration time of the radiation detector
- 6.8 Temperature and humidity
- 6.9 Electromagnetic compatibility [Go to Page]
- 6.9.1 Electrostatic discharge
- 6.9.2 Radiated electromagnetic fields
- 6.9.3 Conducted disturbances induced by bursts and radio frequencies
- 6.9.4 Voltage dips, short interruptions and voltage variations
- 6.10 Field size
- 6.11 Effective length and spatial uniformity of response of CT dosimeters
- 7 Marking [Go to Page]
- 7.1 Detector assembly
- 7.2 Measuring assembly
- 7.3 Radioactive stability check device
- 8 Accompanying documents
- Annex A (informative) Combined standard uncertainty for dosimeter performance
- Bibliography
- Index of defined terms
- Tables [Go to Page]
- Table 1 – Reference and standard test conditions
- Table 2 – Number of readings required to detect true differences Δ (95 % confidence level) between two sets of instrument readings
- Table 3 – Maximum values for the coefficient of variation, vmax, for measurements in the attenuated beam
- Table 4 – Maximum values for the coefficient of variation, vmax, for measurements in the unattenuated beam and mammography
- Table 5 – Limits of variation for the effects of influence quantities
- Table 6 – Climatic conditions
- Table A.1 – Estimation of combined standard uncertainty for dosimeter performance
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d’application et objet [Go to Page]
- 1.1 Domaine d'application
- 1.2 Objet
- 2 Références normatives
- 3 Termes et définitions
- 4 Exigences générales [Go to Page]
- 4.1 Exigences de performance
- 4.2 Valeurs de référence et valeurs d’essai normalisées
- 4.3 Conditions générales d’essai [Go to Page]
- 4.3.1 Conditions d'essai normalisées
- 4.3.2 Variations statistiques
- 4.3.3 Temps de stabilisation
- 4.3.4 Réglages pendant l’essai
- 4.3.5 Batteries
- 4.4 Exigences de construction associées à la performance [Go to Page]
- 4.4.1 Composants
- 4.4.2 Affichage
- 4.4.3 Indication de l’état des batteries
- 4.4.4 Indication d’un défaut de tension de polarisation
- 4.4.5 Dépassement de plage
- 4.4.6 Ensembles de mesurage à ensembles de détection multiples
- 4.4.7 Contrôleur de constance radioactif
- 4.5 Incertitude de mesure
- 5 Limites des caractéristiques de performance [Go to Page]
- 5.1 Linéarité
- 5.2 Répétabilité [Go to Page]
- 5.2.1 Généralités
- 5.2.2 Répétabilité dans le faisceau atténué
- 5.2.3 Répétabilité dans le faisceau non atténué
- 5.3 Pouvoir de résolution du relevé
- 5.4 Temps de stabilisation
- 5.5 Effet du rayonnement pulsé sur les mesurages de kerma dans l’air et du produit kerma dans l’air longueur
- 5.6 Stabilité [Go to Page]
- 5.6.1 Stabilité à long terme
- 5.6.2 Stabilité pour des doses cumulées
- 5.7 Mesurages avec contrôleur de constance radioactif
- 6 Limites de variation pour les effets des grandeurs d’influence [Go to Page]
- 6.1 Généralités
- 6.2 Dépendance de la réponse en énergie
- 6.3 Dépendance des mesurages de kerma dans l’air et du produit kerma dans l’air longueur en débit de kerma dans l’air
- 6.4 Dépendance de la réponse du détecteur par rapport à l'angle d'incidence du rayonnement [Go to Page]
- 6.4.1 Détecteurs hors tomodensitométrie
- 6.4.2 Détecteurs en tomodensitométrie
- 6.5 Tension de fonctionnement [Go to Page]
- 6.5.1 Dosimètres alimentés par le réseau
- 6.5.2 Dosimètres fonctionnant sur batterie
- 6.5.3 Dosimètres fonctionnant sur batterie rechargeable par le réseau
- 6.6 Pression de l’air
- 6.7 Temps de mise en équilibre de la pression de l’air pour le détecteur de rayonnement
- 6.8 Température et humidité
- 6.9 Compatibilité électromagnétique [Go to Page]
- 6.9.1 Décharges électrostatiques
- 6.9.2 Champs électromagnétiques rayonnés
- 6.9.3 Perturbations conduites induites par les salves et les champs radioélectriques
- 6.9.4 Creux de tension, coupures brèves et variations de tension
- 6.10 Dimensions du champ
- 6.11 Longueur effective et uniformité spatiale de la réponse des dosimètres en tomodensitométrie
- 7 Marquage [Go to Page]
- 7.1 Ensemble de détection
- 7.2 Ensemble de mesurage
- 7.3 Contrôleur de constance radioactif
- 8 Documents d'accompagnement
- Annexe A (informative) Incertitude normalisée combinée pour la performance d’un dosimètre
- Bibliographie
- Index des termes définis
- Tableaux [Go to Page]
- Tableau 1 – Conditions d’essai de référence et normalisées
- Tableau 2 – Nombre de relevés exigés pour détecter les différences vraies Δ (niveau de confiance 95 %) entre deux séries de relevés d'instrument
- Tableau 3 – Valeurs maximales du coefficient de variation, vmax, en vue des mesurages dans le faisceau atténué
- Tableau 4 – Valeurs maximales du coefficient de variation, vmax, en vue des mesurages dans le faisceau non atténué et la mammographie
- Tableau 5 – Limites de variation pour les effets des grandeurs d’influence
- Tableau 6 – Conditions climatiques
- Tableau A.1 – Estimation de l’incertitude normalisée combinée pour la performance d’un dosimètre [Go to Page]