Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

IEC 62321-4 Ed. 1.1 b:2017 Determination of certain substances in electrotechnical products - Part 4: Mercury in polymers, metals and electronics by CV-AAS, CV-AFS, ICP-OES and ICP-MS, 2017
- Redline version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviations [Go to Page]
- 3.1 Terms and definitions
- 3.2 Abbreviations
- 4 Reagent and materials [Go to Page]
- 4.1 General
- 4.2 Reagents
- 4.3 Materials
- 5 Apparatus [Go to Page]
- 5.1 General
- 5.2 Apparatus
- 6 Sampling and test portion
- 7 Procedure [Go to Page]
- 7.1 Wet digestion (digestion of electronics)
- 7.2 Microwave digestion
- 7.3 Thermal decomposition-gold amalgamation system
- 7.4 Preparation of reagent blank solution
- 8 Calibration [Go to Page]
- 8.1 General
- 8.2 Development of the calibration curve
- 8.3 Measurement of the sample
- 9 Calculation
- 10 Precision
- 11 Quality assurance and control [Go to Page]
- 11.1 General
- 11.2 Limits of detection (LOD) and limits of quantification (LOQ)
- Annex A (informative) Practical application of determination of mercury in polymers, metals and electronics by CV-AAS, AFS, ICP-OES and ICP-MS
- Annex B (informative) Results of international interlaboratory study Nos. 2 (IIS2) and 4A (IIS 4A)
- Bibliography
- Tables [Go to Page]
- Table 1 – Repeatability and reproducibility
- Table 2 – Acceptance criteria of items for the quality control
- Table 3 – Method detection limit = t × sn–1
- Table A.1 – Program for microwave digestion (example) of samples (power output for five vessels)
- Table B.1 – Statistical data for TD(G)-AAS
- Table B.2 – Statistical data for CV-AAS
- Table B.3 – Statistical data for CV-AFS
- Table B.4 – Statistical data for ICP-OES
- Figures [Go to Page]
- Figure A.1 – Heating digester equipped with reaction vessel,reflux cooler and absorption vessel
- Figure A.2 – Configuration of equipment with AAS (example)
- Figure A.3 – Mercury collecting tube (example)
- Figure A.4 – Configuration (example) of the thermal decomposition/atomic absorption spectrometer for CCFL
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes, définitions et abréviations [Go to Page]
- 3.1 Termes et définitions
- 3.2 Abréviations
- 4 Réactifs et matériaux [Go to Page]
- 4.1 Généralités
- 4.2 Réactifs
- 4.3 Matériaux
- 5 Appareillage [Go to Page]
- 5.1 Généralités
- 5.2 Appareillage
- 6 Echantillonnage et prise d'essai
- 7 Procédure [Go to Page]
- 7.1 Digestion par voie humide (digestion de produits électroniques)
- 7.2 Digestion aux micro-ondes
- 7.3 Système de décomposition thermique-amalgame d'or
- 7.4 Préparation de la solution à base de réactif témoin
- 8 Etalonnage [Go to Page]
- 8.1 Généralités
- 8.2 Elaboration de la courbe d'étalonnage
- 8.3 Mesure de l'échantillon
- 9 Calculs
- 10 Précision
- 11 Assurance et contrôle qualité [Go to Page]
- 11.1 Généralités
- 11.2 Limites de détection (LOD) et limites de quantification (LOQ)
- Annexe A (informative) Application pratique de la détermination du mercure dans les polymères, les métaux et les produits électroniques par CV-AAS, AFS, ICP-OES et ICP-MS
- Annexe B (informative) Résultats des études internationales inter-laboratoires n 2 (IIS2) et 4A (IIS 4A)
- Bibliographie
- Tableaux [Go to Page]
- Tableau 1 – Répétabilité et reproductibilité
- Tableau 2 – Critères d’acceptation des éléments pour le contrôle qualité
- Tableau 3 – Limite de détection de la méthode = t × sn–1
- Tableau A.1 – Programme de digestion (exemple) des échantillons aux micro-ondes (puissance fournie pour cinq récipients)
- Tableau B.1 – Données statistiques pour TD(G)-AAS
- Tableau B.2 – Données statistiques pour CV-AAS
- Tableau B.3 – Données statistiques pour CV-AFS
- Tableau B.4 – Données statistiques pour ICP-OES
- Figures [Go to Page]
- Figure A.1 – Digesteur chauffant équipé d'un récipient de réaction, d'un réfrigérant à reflux et d'un récipient d'absorption
- Figure A.2 – Configuration de l'équipement avec AAS (exemple)
- Figure A.3 – Tube collecteur de mercure (exemple)
- Figure A.4 – Configuration (exemple) du spectromètre d'absorption atomique à décomposition thermique pour CCFL
- Final version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviations [Go to Page]
- 3.1 Terms and definitions
- 3.2 Abbreviations
- 4 Reagent and materials [Go to Page]
- 4.1 General
- 4.2 Reagents
- 4.3 Materials
- 5 Apparatus [Go to Page]
- 5.1 General
- 5.2 Apparatus
- 6 Sampling and test portion
- 7 Procedure [Go to Page]
- 7.1 Wet digestion (digestion of electronics)
- 7.2 Microwave digestion
- 7.3 Thermal decomposition-gold amalgamation system
- 7.4 Preparation of reagent blank solution
- 8 Calibration [Go to Page]
- 8.1 General
- 8.2 Development of the calibration curve
- 8.3 Measurement of the sample
- 9 Calculation
- 10 Precision
- 11 Quality assurance and control [Go to Page]
- 11.1 General
- 11.2 Limits of detection (LOD) and limits of quantification (LOQ)
- Annex A (informative) Practical application of determination of mercury in polymers, metals and electronics by CV-AAS, AFS, ICP-OES and ICP-MS
- Annex B (informative) Results of international interlaboratory study Nos. 2 (IIS2) and 4A (IIS 4A)
- Bibliography
- Tables [Go to Page]
- Table 1 – Repeatability and reproducibility
- Table 2 – Acceptance criteria of items for the quality control
- Table 3 – Method detection limit = t × sn–1
- Table A.1 – Program for microwave digestion (example) of samples (power output for five vessels)
- Table B.1 – Statistical data for TD(G)-AAS
- Table B.2 – Statistical data for CV-AAS
- Table B.3 – Statistical data for CV-AFS
- Table B.4 – Statistical data for ICP-OES
- Figures [Go to Page]
- Figure A.1 – Heating digester equipped with reaction vessel,reflux cooler and absorption vessel
- Figure A.2 – Configuration of equipment with AAS (example)
- Figure A.3 – Mercury collecting tube (example)
- Figure A.4 – Configuration (example) of the thermal decomposition/atomic absorption spectrometer for CCFL
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes, définitions et abréviations [Go to Page]
- 3.1 Termes et définitions
- 3.2 Abréviations
- 4 Réactifs et matériaux [Go to Page]
- 4.1 Généralités
- 4.2 Réactifs
- 4.3 Matériaux
- 5 Appareillage [Go to Page]
- 5.1 Généralités
- 5.2 Appareillage
- 6 Echantillonnage et prise d'essai
- 7 Procédure [Go to Page]
- 7.1 Digestion par voie humide (digestion de produits électroniques)
- 7.2 Digestion aux micro-ondes
- 7.3 Système de décomposition thermique-amalgame d'or
- 7.4 Préparation de la solution à base de réactif témoin
- 8 Etalonnage [Go to Page]
- 8.1 Généralités
- 8.2 Elaboration de la courbe d'étalonnage
- 8.3 Mesure de l'échantillon
- 9 Calculs
- 10 Précision
- 11 Assurance et contrôle qualité [Go to Page]
- 11.1 Généralités
- 11.2 Limites de détection (LOD) et limites de quantification (LOQ)
- Annexe A (informative) Application pratique de la détermination du mercure dans les polymères, les métaux et les produits électroniques par CV-AAS, AFS, ICP-OES et ICP-MS
- Annexe B (informative) Résultats des études internationales inter-laboratoires n 2 (IIS2) et 4A (IIS 4A)
- Bibliographie
- Tableaux [Go to Page]
- Tableau 1 – Répétabilité et reproductibilité
- Tableau 2 – Critères d’acceptation des éléments pour le contrôle qualité
- Tableau 3 – Limite de détection de la méthode = t × sn–1
- Tableau A.1 – Programme de digestion (exemple) des échantillons aux micro-ondes (puissance fournie pour cinq récipients)
- Tableau B.1 – Données statistiques pour TD(G)-AAS
- Tableau B.2 – Données statistiques pour CV-AAS
- Tableau B.3 – Données statistiques pour CV-AFS
- Tableau B.4 – Données statistiques pour ICP-OES
- Figures [Go to Page]
- Figure A.1 – Digesteur chauffant équipé d'un récipient de réaction, d'un réfrigérant à reflux et d'un récipient d'absorption
- Figure A.2 – Configuration de l'équipement avec AAS (exemple)
- Figure A.3 – Tube collecteur de mercure (exemple)
- Figure A.4 – Configuration (exemple) du spectromètre d'absorption atomique à décomposition thermique pour CCFL [Go to Page]