Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

IEC 62386-302 Ed. 1.1 en:2024 Digital addressable lighting interface - Part 302: Particular requirements - Input devices - Absolute input devices, 2024
- Redline version [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General [Go to Page]
- 4.1 General
- 4.2 Version number
- 4.3 Insulation
- 5 Electrical specification
- 6 Interface power supply
- 7 Transmission protocol structure
- 8 Timing
- 9 Method of operation [Go to Page]
- 9.1 General
- 9.2 Instance type
- 9.3 Input signal and value [Go to Page]
- 9.3.1 General
- 9.3.2 Binary inputs
- 9.3.3 Analogue inputs
- 9.4 Events [Go to Page]
- 9.4.1 Priority use
- 9.4.2 Bus usage
- 9.4.3 Encoding
- 9.4.4 Event configuration
- 9.4.5 Event generation
- 9.5 Configuring the input device [Go to Page]
- 9.5.1 Using the report timer
- 9.5.2 Using the deadtime timer
- 9.5.3 Setting the timers
- 9.5.4 Manual configuration
- 9.6 Exception handling [Go to Page]
- 9.6.1 Manufacturer specific errors
- 9.6.2 Error value
- 10 Declaration of variables
- 11 Definition of commands [Go to Page]
- 11.1 General
- 11.2 Overview sheets [Go to Page]
- 11.2.1 General
- 11.2.2 Standard commands
- 11.3 Event messages [Go to Page]
- 11.3.1 INPUT NOTIFICATION (device/instance, event)
- 11.3.2 POWER NOTIFICATION (device)
- 11.4 Device control instructions
- 11.5 Device configuration instructions
- 11.6 Device queries
- 11.7 Instance control instructions
- 11.8 Instance configuration instructions [Go to Page]
- 11.8.1 General
- 11.8.2 SET REPORT TIMER (DTR0)
- 11.8.3 SET DEADTIME TIMER (DTR0)
- 11.8.4 SET EVENT FILTER (DTR0)
- 11.9 Instance queries [Go to Page]
- 11.9.1 General
- 11.9.2 QUERY INSTANCE ERROR
- 11.9.3 QUERY DEADTIME TIMER
- 11.9.4 QUERY REPORT TIMER
- 11.9.5 QUERY SWITCH
- 11.10 Special commands
- Annex A (normative) Examples of connecting external switches or sliders [Go to Page]
- A.1 Single switch
- A.2 Single switch, two positions
- A.3 Single switch with neutral position
- A.4 Rotary switch
- A.5 Slider
- Bibliography
- Figures [Go to Page]
- Figure 1 – IEC 62386 graphical overview
- Figure A.1 – Single switch (single-pole, single-throw)
- Figure A.2 – Single switch double throw (single-pole, double-throw)
- Figure A.3 – Single switch (single-pole, double-throw) with neutral position
- Figure A.4 – Rotary switch
- Figure A.5 – Slider
- Tables [Go to Page]
- Table 1 – Relation of input signal and "inputValue"
- Table 2 – Position events
- Table 3 – Event filter
- Table 4 – Event timer setting
- Table 5 – “manualCapabilityInstance3xx” values
- Table 6 – “instanceErrorByte” values
- Table 7 – Declaration of device variables
- Table 8 – Restrictions to instance variables defined in IEC 62386-103:2022
- Table 9 – Declaration of instance variables
- Table 10 – Standard commands
- Final version [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General [Go to Page]
- 4.1 General
- 4.2 Version number
- 4.3 Insulation
- 5 Electrical specification
- 6 Interface power supply
- 7 Transmission protocol structure
- 8 Timing
- 9 Method of operation [Go to Page]
- 9.1 General
- 9.2 Instance type
- 9.3 Input signal and value [Go to Page]
- 9.3.1 General
- 9.3.2 Binary inputs
- 9.3.3 Analogue inputs
- 9.4 Events [Go to Page]
- 9.4.1 Priority use
- 9.4.2 Bus usage
- 9.4.3 Encoding
- 9.4.4 Event configuration
- 9.4.5 Event generation
- 9.5 Configuring the input device [Go to Page]
- 9.5.1 Using the report timer
- 9.5.2 Using the deadtime timer
- 9.5.3 Setting the timers
- 9.5.4 Manual configuration
- 9.6 Exception handling [Go to Page]
- 9.6.1 Manufacturer specific errors
- 9.6.2 Error value
- 10 Declaration of variables
- 11 Definition of commands [Go to Page]
- 11.1 General
- 11.2 Overview sheets [Go to Page]
- 11.2.1 General
- 11.2.2 Standard commands
- 11.3 Event messages [Go to Page]
- 11.3.1 INPUT NOTIFICATION (device/instance, event)
- 11.3.2 POWER NOTIFICATION (device)
- 11.4 Device control instructions
- 11.5 Device configuration instructions
- 11.6 Device queries
- 11.7 Instance control instructions
- 11.8 Instance configuration instructions [Go to Page]
- 11.8.1 General
- 11.8.2 SET REPORT TIMER (DTR0)
- 11.8.3 SET DEADTIME TIMER (DTR0)
- 11.8.4 SET EVENT FILTER (DTR0)
- 11.9 Instance queries [Go to Page]
- 11.9.1 General
- 11.9.2 QUERY INSTANCE ERROR
- 11.9.3 QUERY DEADTIME TIMER
- 11.9.4 QUERY REPORT TIMER
- 11.9.5 QUERY SWITCH
- 11.10 Special commands
- Annex A (normative) Examples of connecting external switches or sliders [Go to Page]
- A.1 Single switch
- A.2 Single switch, two positions
- A.3 Single switch with neutral position
- A.4 Rotary switch
- A.5 Slider
- Bibliography
- Figures [Go to Page]
- Figure 1 – IEC 62386 graphical overview
- Figure A.1 – Single switch (single-pole, single-throw)
- Figure A.2 – Single switch double throw (single-pole, double-throw)
- Figure A.3 – Single switch (single-pole, double-throw) with neutral position
- Figure A.4 – Rotary switch
- Figure A.5 – Slider
- Tables [Go to Page]
- Table 1 – Relation of input signal and "inputValue"
- Table 2 – Position events
- Table 3 – Event filter
- Table 4 – Event timer setting
- Table 5 – “manualCapabilityInstance3xx” values
- Table 6 – “instanceErrorByte” values
- Table 7 – Declaration of device variables
- Table 8 – Restrictions to instance variables defined in IEC 62386-103:2022
- Table 9 – Declaration of instance variables
- Table 10 – Standard commands [Go to Page]