Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

IEC 62554 Ed. 1.1 b:2017 Sample preparation for measurement of mercury level in fluorescent lamps, 2017
- Redline version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General
- 5 Procedure for collecting mercury from a fluorescent lamp [Go to Page]
- 5.1 General
- 5.2 Reagents
- 5.3 Chemical lab ware
- 5.4 Sample preparation [Go to Page]
- 5.4.1 Cold spotting methods
- 5.4.2 Sample preparation of fluorescent lamps by non-cold-spot (sectioning) methods
- 5.4.3 Sample preparation of fluorescent lamps by non-cold-spot (crushing) methods
- 5.4.4 Nitric acid rinse method for linear fluorescent lamps
- 5.4.5 Direct mercury measurement
- 5.4.6 Sample preparation of other fluorescent lamps
- 5.5 Sample digestion [Go to Page]
- 5.5.1 Ambient conditions
- 5.5.2 Glass samples (in 250 ml, 500 ml, 1 000 ml or 2 000 ml container)
- 5.5.3 Metal samples (in 125 ml container)
- 5.6 Filtering
- 6 Measurement [Go to Page]
- 6.1 Blank test
- 6.2 Data reporting
- 6.3 Analysis
- Annex A (informative) Electrothermal vaporization atomic absorption spectrometry (EVAAS) method
- Annex B (informative) Information on the cold spotting method
- Bibliography
- Figures [Go to Page]
- Figure A.1 – Configuration of the electrothermal vaporization atomic absorption spectrometry testing apparatus
- Figure A.2 – An example of the electrothermal vaporization atomic absorption spectrometer test apparatus layout
- Figure B.1 – Example of glass cell arrangement
- Figure B.2 – Example of cooling device arrangement
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l'Amendement 1
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes et définitions
- 4 Généralités
- 5 Procédure pour recueillir le mercure d’une lampe fluorescente [Go to Page]
- 5.1 Généralités
- 5.2 Réactifs
- 5.3 Matériel chimique de laboratoire
- 5.4 Préparation des échantillons [Go to Page]
- 5.4.1 Méthodes de réalisation par le point froid
- 5.4.2 Préparation des échantillons de lampes fluorescentes par des méthodes (de sectionnement) sans point froid
- 5.4.3 Préparation des échantillons de lampes fluorescentes par des méthodes (d'écrasement) sans point froid
- 5.4.4 Méthode de rinçage à l’acide nitrique concernant les lampes fluorescentes linéaires
- 5.4.5 Mesure directe du mercure
- 5.4.6 Préparation des échantillons d'autres lampes fluorescentes
- 5.5 Digestion des échantillons [Go to Page]
- 5.5.1 Conditions ambiantes
- 5.5.2 Échantillons de verre (dans un récipient de 250 ml, 500 ml, 1 000 ml ou 2 000 ml)
- 5.5.3 Échantillons de métal (dans un récipient de 125 ml)
- 5.6 Filtrage
- 6 Mesure [Go to Page]
- 6.1 Essai à blanc
- 6.2 Consignation des données
- 6.3 Analyse
- Annexe A (informative) Méthode de la spectrométrie d’absorption atomique à vaporisation électrothermique (EVAAS, electrothermal vaporization atomic absorption spectrometry)
- Annexe B (informative) Informations relatives à la méthode de la réalisation du point froid
- Bibliographie
- Figures [Go to Page]
- Figure A.1 – Configuration de l’appareillage d’essai de la spectrométrie d’absorption atomique à vaporisation électrothermique
- Figure A.2 – Exemple de dispositif d’appareillage d’essai au spectromètre d’absorption atomique à vaporisation électrothermique
- Figure B.1 – Exemple de montage de cellule de verre
- Figure B.2 – Exemple de montage du dispositif de refroidissement
- Final version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General
- 5 Procedure for collecting mercury from a fluorescent lamp [Go to Page]
- 5.1 General
- 5.2 Reagents
- 5.3 Chemical lab ware
- 5.4 Sample preparation [Go to Page]
- 5.4.1 Cold spotting methods
- 5.4.2 Sample preparation of fluorescent lamps by non-cold-spot (sectioning) methods
- 5.4.3 Sample preparation of fluorescent lamps by non-cold-spot (crushing) methods
- 5.4.4 Nitric acid rinse method for linear fluorescent lamps
- 5.4.5 Direct mercury measurement
- 5.4.6 Sample preparation of other fluorescent lamps
- 5.5 Sample digestion [Go to Page]
- 5.5.1 Ambient conditions
- 5.5.2 Glass samples (in 250 ml, 500 ml, 1 000 ml or 2 000 ml container)
- 5.5.3 Metal samples (in 125 ml container)
- 5.6 Filtering
- 6 Measurement [Go to Page]
- 6.1 Blank test
- 6.2 Data reporting
- 6.3 Analysis
- Annex A (informative) Electrothermal vaporization atomic absorption spectrometry (EVAAS) method
- Annex B (informative) Information on the cold spotting method
- Bibliography
- Figures [Go to Page]
- Figure A.1 – Configuration of the electrothermal vaporization atomic absorption spectrometry testing apparatus
- Figure A.2 – An example of the electrothermal vaporization atomic absorption spectrometer test apparatus layout
- Figure B.1 – Example of glass cell arrangement
- Figure B.2 – Example of cooling device arrangement
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l'Amendement 1
- 1 Domaine d'application
- 2 Références normatives
- 3 Termes et définitions
- 4 Généralités
- 5 Procédure pour recueillir le mercure d’une lampe fluorescente [Go to Page]
- 5.1 Généralités
- 5.2 Réactifs
- 5.3 Matériel chimique de laboratoire
- 5.4 Préparation des échantillons [Go to Page]
- 5.4.1 Méthodes de réalisation par le point froid
- 5.4.2 Préparation des échantillons de lampes fluorescentes par des méthodes (de sectionnement) sans point froid
- 5.4.3 Préparation des échantillons de lampes fluorescentes par des méthodes (d'écrasement) sans point froid
- 5.4.4 Méthode de rinçage à l’acide nitrique concernant les lampes fluorescentes linéaires
- 5.4.5 Mesure directe du mercure
- 5.4.6 Préparation des échantillons d'autres lampes fluorescentes
- 5.5 Digestion des échantillons [Go to Page]
- 5.5.1 Conditions ambiantes
- 5.5.2 Échantillons de verre (dans un récipient de 250 ml, 500 ml, 1 000 ml ou 2 000 ml)
- 5.5.3 Échantillons de métal (dans un récipient de 125 ml)
- 5.6 Filtrage
- 6 Mesure [Go to Page]
- 6.1 Essai à blanc
- 6.2 Consignation des données
- 6.3 Analyse
- Annexes [Go to Page]
- Annexe A (informative) Méthode de la spectrométrie d’absorption atomiqueà vaporisation électrothermique (EVAAS, electrothermal vaporization atomic absorption spectrometry)
- Annexe B (informative) Informations relatives à la méthode de la réalisation du point froid
- Bibliographie
- Figures [Go to Page]
- Figure A.1 – Configuration de l’appareillage d’essai de la spectrométrie d’absorption atomique à vaporisation électrothermique
- Figure A.2 – Exemple de dispositif d’appareillage d’essai au spectromètre d’absorption atomique à vaporisation électrothermique
- Figure B.1 – Exemple de montage de cellule de verre
- Figure B.2 – Exemple de montage du dispositif de refroidissement [Go to Page]