ISO 5599-2:2001 Pneumatic fluid power - Five-port directional control valves - Part 2: Mounting interface surfaces with optional electrical connector, 2001
- Pneumatic fluid power— Five-port directional control valves—
- Contents Page
- Foreword
- Introduction
- Pneumatic fluid power— Five-port directional control valves— [Go to Page]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Dimensional requirements and tolerances [Go to Page]
- 4.1 Dimensional requirements for sizes1E, 2E and 3E are shown in Figure
- 4.2 Dimensional requirements for sizes4E, 5E and 6E are shown in Figure
- 4.3 The main dimensions and tolerances of form and location of the interface features are show...
- 4.4 Tolerances on surface condition, within the continuous lines, shall be as follows:
- 4.5 The mounting surface shall not include any orifices other than those shown in the figures....
- 5 Identification of ports and orifices [Go to Page]
- 5.1 The flow path orifices in the mounting surface interface, and the ports serving these orif...
- 5.2 For monostable valves, the mandatory stable position of the valve shall always be identica...
- 5.3 When a positive signal is applied to control mechanism12, flow port1 shall be connected ...
- 5.4 The orientation of control mechanisms12 and 14 on the valve relative to flow ports2, 3, ...
- 5.5 Additional options for port identification shall be in accordance with
- 6 Electrical connector [Go to Page]
- 6.1 General
- 6.2 Connector [Go to Page]
- 6.2.1 The connector shall be readily removable, if not required, and shall comply with the req...
- 6.2.2 Connectors shall be rated at
- 6.2.3 Connectors shall be rated at
- 6.2.4 Insulated leads shall be rated at
- 6.3 Contacts [Go to Page]
- 6.3.1 Each connector shall comprise four live contacts and one earth contact. The earth contac...
- 6.3.2 The pins shall have diameters of
- 6.3.3 Socket contacts shall have an opening that allows friction fits on the pin contacts.
- 6.4 Insulation [Go to Page]
- 6.4.1 Wire of a sectional area of from
- 6.4.2 Same-colour insulation on diagonally opposite leads shall be used.
- 6.4.3 Green insulation shall identify the earth connection.
- 6.5 Orientation [Go to Page]
- 6.5.1 The dimensions of the electrical connector shall conform to those given in Figure
- 6.5.2 The contacts shall be located at the corners of a rectangle, with the earth at the centre.
- 6.5.3 Contacts1 and 4 shall be oriented parallel to the valve port slots and towards the valv...
- 6.5.4 Contacts1 and 3 shall be used with single solenoid valves.
- 6.5.5 Contacts2 and 4 shall be used with the second solenoid of a double solenoid valve.
- 6.5.6 Contact5 shall be the earth ground.
- 6.5.7 Each connector half shall be kept in place when the valve body and base are disconnected.
- 7 Identification statement