Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(366)
(651)
(599)
(57)
(290)
(1055)
(727)
(2283)
(117)
(98251)
(58)
(643)
(137)
(36)
(29)
(20)
(99791)
(18)
(1)
(396)
(328)
(10763)
(7368)
(265)
(21)
(24376)
(914)
(7)
(1729)
(26)
(19)
(28)
(4)
 
(6)
(7)
(128)
(1)
(4)
(58)
(5)
(5)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(27)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ASTM
    D6908-06(2010) Standard Practice for Integrity Testing of Water Filtration Membrane Systems
    Edition: 2010
    $144.00
    Unlimited Users per year

Description of ASTM-D6908 2010

ASTM D6908-06-Reapproved2010

Historical Standard: Standard Practice for Integrity Testing of Water Filtration Membrane Systems




ASTM D6908

Scope

1.1 This practice covers the determination of the integrity of water filtration membrane elements and systems using air based tests (pressure decay and vacuum hold), soluble dye, continuous monitoring particulate light scatter techniques, and TOC monitoring tests for the purpose of rejecting particles and microbes. The tests are applicable to systems with membranes that have a nominal pore size less than about 1 µm. The TOC, and Dye, tests are generally applicable to NF and RO class membranes only.

1.2 This practice does not purport to cover all available methods of integrity testing.

1.3 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

7.1 This practice covers the determination of integrity for membrane systems using the pressure decay test (PDT) and vacuum decay test (VDT).

7.2 The tests may be used on membranes in all classes, RO through MF, and are suitable for hollow fibers, tubular and flat sheet (such as spiral wound) configurations. However, the PDT is most commonly employed for in-situ testing of UF and MF systems and the VDT for testing NF and RO elements and systems. See Practice D3923.

10.1 This practice is applicable where the membrane system and water source will allow the monitoring of TOC both upstream and downstream of the system, and at least order of magnitude difference from the feed can be measured in the permeate (product) water. See D4839.

16.1 This guide is applicable to RO and NF membrane systems, including those with spiral, tubular or flat sheet configuration elements. The guide describes the application of two soluble dyes, Red Dye # 40 and Rhodamine WT. Both dyes have a molecular weight of approximately 500. See Practice D3923.

22.1 This guide is applicable to MF, UF, NF, and RO membrane systems, including those with spiral, tubular or flat sheet configuration elements. The feedwater must have a particulate concentration that is at least an order of magnitude in higher concentration than that which is detected in the filtrate or permeate stream. This practice is applicable for those membrane systems and that will allow for the monitoring of the water source and in the filtrate or permeate stream as it exists a membrane module.

22.2 For turbidity techniques, the feedwater should have a turbidity of at least 0.5 NTU (500 mNTU) and for particle counting techniques, the feedwater should have a count concentration of at least 1 particle per mL greater than the defined size threshold that is being applied.

22.3 This practice provides for the use of two different laser based particulate detection technologies: optical particle counting (light obscuration designs) and laser turbidity (light scattering). , Liquid or sensor multiplexing with either of these two technologies is possible and can increase sensitivity and facilitate defect identification.

22.4 This method provides for the continuous monitoring of each sample point. Flow through the sample point (that is, the sensor) is continuous, and the measurement frequency is at least every 15-min during filtration.


Keywords

continuous monitoring; integrity; membrane; multiplexing; pressure decay; soluble dye test; TOC test; vacuum decay; Dye tracers; Filters/filter procedures--water testing; Integrity testing; Membrane filters (MF)--water testing; Pressure decay; Soluble dye test; TOC test; Vacuum decay


ICS Code

ICS Number Code 13.060.01 (Water quality in general)


DOI: 10.1520/D6908-06R10



This book also exists in the following packages...

Year Publisher Title Annual Price
VAR
ASTM
[+] $1,382.78 Buy
VAR
ASTM
[+] $7,192.78 Buy

Subscription Information

MADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

Some features of MADCAD.com ASTM Standards Subscriptions are:

- Online access: With MADCAD.com’ s web based subscription service no downloads or installations are required. Access ASTM Standards from any browser on your computer, tablet or smart phone.

- Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.

 

For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.

 

About ASTM

ASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide.

X