ASTM E966-04
Historical Standard: ASTM E966-04 Standard Guide for Field Measurements of Airborne Sound Insulation of Building Facades and Facade Elements
SUPERSEDED (see Active link, below)
ASTM E966
1. Scope
1.1 This guide covers field procedures for measuring the sound level reduction or sound transmission loss of an installed building facade or facade element in specified frequency bands. These values may be used separately to predict interior levels or combined into a single number such as by Classification E 413 (with precautions) or Classification E 1332 to estimate the sound insulating properties of the test element, FOITC, in the field. The results are applicable to installations similar to that tested when exposed to an outdoor sound field similar to that used during the measurement.
1.1.1 The facade element may be the exterior wall of a room in the building, or a portion of that wall such as a door or window, when the remainder of that wall has substantially greater sound insulation than the portion under test.
1.2 To cope with the variety of outdoor test geometry that may be encountered, several testing techniques are presented. These techniques and their general applicability are summarized in and .
1.3 This guide may be used to determine the outdoor-indoor level reduction (OILR), which is the difference in sound pressure between a specified outdoor sound field and the resulting sound pressure level in the room abutting the test facade or facade element. The outdoor sound field and its measurement must be thoroughly described. The resulting level reduction or transmission loss value will depend on the outdoor field geometry and the point at which it is measured or represented.
1.4 The values stated in SI units are to be regarded as standard. The values given in parentheses are provided for information only.
This standard does not purport to address the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
C634 Terminology Relating to Building and Environmental Acoustics
E90 Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements
E336 Test Method for Measurement of Airborne Sound Attenuation between Rooms in Buildings
E492 Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine
E1007 Test Method for Field Measurement of Tapping Machine Impact Sound Transmission Through Floor-Ceiling Assemblies and Associated Support Structures
E1332 Classification for Rating Outdoor-Indoor Sound Attenuation
E1414 Test Method for Airborne Sound Attenuation Between Rooms Sharing a Common Ceiling Plenum
E2235 Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods
Keywords
calibrated loudspeaker; doors; facade; flanking; noise reduction; outdoor noise field; outdoor-indoor level reduction; outdoor-indoor transmission loss; traffic noise; transmission loss; windows;: Airborne sound analysis; Building facades; Calibrated loudspeaker; Doors/door assemblies; Field testing--sound transmission; Flanking sound transmission/analysis; Impact sound transmission (building elements); Noise reduction; Outdoor sound measurement; Sound transmission--building materials/applications; Traffic noise; Transmission loss; Windows/window assemblies;
ICS Code
ICS Number Code 91.120.20 (Acoustics in buildings. Sound insulation)
DOI: 10.1520/E0966-04