Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(366)
(651)
(599)
(57)
(290)
(1055)
(738)
(2283)
(117)
(99009)
(58)
(650)
(137)
(42)
(29)
(20)
(102918)
(18)
(1)
(397)
(328)
(10763)
(7368)
(266)
(21)
(24376)
(1010)
(7)
(1737)
(26)
(19)
(28)
(4)
 
(6)
(7)
(128)
(1)
(4)
(58)
(5)
(7)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(27)
(7)
(8)
(20)
(1)
(3)
(50)
(7)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS ISO 8769:2020 Measurement of radioactivity. Alpha-, beta- and photon emitting radionuclides. Reference measurement standard specifications for the calibration of surface contamination monitors
    Edition: 2020
    $315.02
    / user per year

Description of BS ISO 8769:2020 2020

This document specifies the characteristics of reference measurement standards of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This document relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV.

It does not describe the procedures involved in the use of these reference measurement standards for the calibration of surface contamination monitors. Such procedures are specified in IEC 60325[ 6], IEC 62363[ 7], and other documents.

NOTE

Since some of the proposed photon standards include filters, the photon standards are to be regarded as reference measurement standards of photons of a particular energy range and not as reference measurement standards of a particular radionuclide. For example, a 241Am source with the recommended filtration does not emit from the surface the alpha particles or characteristic low-energy L X-ray photons associated with the decay of the nuclide. It is designed to be a reference measurement standard that emits photons with an average energy of approximately 60 keV.

This document also specifies preferred reference radiations for the calibration of surface contamination monitors. These reference radiations are realized in the form of adequately characterized large area sources specified, without exception, in terms of surface emission rate and activity which are traceable to national standards.





About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X