|
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content DescriptionThis document specifies a large-scale fire test method for measuring the heat release rate (HRR) and the smoke-production rate (SPR) of wall systems. The fire scenario covered in this document is representative of severe fires originating in near wall or corner locations of an exterior or interior wall construction. A severe fire scenario is defined that imparts a heat flux on the order of 100Â kW/m2 to the wall systems. These include exterior fire scenarios such as dumpster, balcony storage fires, and vehicle fires originating outside buildings. Fires caused by combustible storage inside unsprinklered or inadequately sprinklered occupancies, such as warehouse and manufacturing occupancies, represent a few examples of severe interior fires. This document measures the HRR and SPR in accordance with ISO 24473. This document also provides guidelines for heat release and smoke production performance limits, developed and used for risk evaluation by the insurance industry. The test method is not applicable to scenarios where a fire initiates within an air cavity, if present, of an exterior wall system. The test method does not incorporate a window structure and is therefore not applicable to fire spread hazards resulting from inadequately protected window openings in a post-flashover fire scenario. About ISOISO, the International Organization for Standardization, brings global experts together to agree on the best way of doing things – for anything from making a product to managing a process. As one of the oldest non-governmental international organizations, ISO has enabled trade and cooperation between people and companies all over the world since 1946. The International Standards published by ISO serve to make lives easier, safer and better. |
GROUPS
|