Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(365)
(651)
(599)
(58)
(290)
(1053)
(728)
(2285)
(117)
(97896)
(58)
(641)
(137)
(35)
(28)
(20)
(99791)
(18)
(1)
(396)
(328)
(10763)
(7368)
(264)
(21)
(24378)
(914)
(7)
(1722)
(23)
(19)
(28)
(4)
 
(6)
(7)
(128)
(1)
(3)
(58)
(5)
(5)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(25)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • ISO
    ISO 6767:1990 Ambient air - Determination of the mass concentration of sulfur dioxide - Tetrachloromercurate (TCM)/pararosaniline method
    Edition: 1990
    $192.38
    / user per year

Content Description

This international Standard specifies a spectrophotometric method, known as the tetrachioromercurate (TCM)/pararosaniline method, for the determination of the mass concentration of sulfur dioxide in ambient air within the range of 20 μg/m3 to about 500 μg/m3.

The sampling period is 30 min to 60 min.

if a longer sampling period than 60 min is used, or higher concentrations of sulfur dioxide (up to about 2000 μg/m3) are expected, care is necessary to ensure that the concentrations of sulfur dioxide in the absorption solution given in clause 6, paragraph 2 are not exceeded. This can be achieved by a reduction of the volume flow rate during sampling. Sample solutions obtained by this procedure may be stored for up to 24 h before making measurements, provided that they are kept in a refrigerator at about 5 °C.

Substances which are known to interfere and which might be present in the air being sampled are listed in 7.5

indications of the precision and accuracy of the method, and of the lower detection limit are given in 8.2.

Detection limit, standard deviations and lnterferences qualify the TCM-method for orientating field measurements in the higher concentration range. When more accurafe measurements are necessary, instruments which are specially tested and calibrated should be used.



About ISO

ISO, the International Organization for Standardization, brings global experts together to agree on the best way of doing things – for anything from making a product to managing a process. As one of the oldest non-governmental international organizations, ISO has enabled trade and cooperation between people and companies all over the world since 1946. The International Standards published by ISO serve to make lives easier, safer and better.

X