Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

BS EN 60695-1-21:2016 Fire hazard testing - Guidance for assessing the fire hazard of electrotechnical products. Ignitability. Summary and relevance of test methods, 2016
- 30309577-VOR.pdf [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Summary of published test methods [Go to Page]
- 4.1 General
- 4.2 Tests using heated air or electrical heating [Go to Page]
- 4.2.1 Determination of ignition temperature using a hot-air furnace, ISO 871
- 4.2.2 Differential scanning calorimetry (DSC), ISO 11357 [1]
- 4.3 Tests using radiant heat [Go to Page]
- 4.3.1 Heat release rate – Cone calorimeter method, ISO 5660-1 [4]
- 4.3.2 Heat release of insulating liquids, IEC TS 60695-8-3 [5]
- 4.3.3 Standard test method for determining material ignition and flame spread properties, ASTM E 1321 [6]
- 4.3.4 Determination of the characteristic heat flux for ignition from a non-contacting flame source, IEC TS 60695-11-11 [7]
- 4.4 Oxygen index tests [Go to Page]
- 4.4.1 Oxygen index – Ambient temperature test, ISO 4589-2 [8]
- 4.4.2 Oxygen index – Elevated temperature test, ISO 4589-3 [10]
- 4.5 Glowing/hot-wire based test methods [Go to Page]
- 4.5.1 Glow wire tests, IEC 60695-2-11 [14], IEC 60695-2-12 [15] and IEC 60695-2-13 [16]
- 4.5.2 Hot wire coil ignitability test, IEC 60695-2-20 and ASTM D 3874 [17]
- 4.6 Flame tests [Go to Page]
- 4.6.1 Needle flame test, IEC 60695-11-5 [18]
- 4.6.2 50 W horizontal and vertical flame test methods, IEC 60695-11-10 [19]; 500 W flame test methods, IEC 60695-11-20 [20]
- 4.6.3 1 kW nominal pre-mixed flame, IEC 60695-11-2 [23]
- 4.6.4 Vertical and 60( tests for aircraft components, FAR 25 [25]
- 4.7 Tests using an electrical arc [Go to Page]
- 4.7.1 Tracking index tests, IEC 60112 [26], ASTM D 3638 [27]
- 4.7.2 High-Current Arc Ignition (HAI), UL 746A – Sec. 32 [30]
- 4.7.3 High-voltage arc resistance to ignition (HVAR), UL 746A – Sec. 33 [31]
- Annex A (informative) Applicability of test methods [Go to Page]
- A.1 Applicability of test methods
- Bibliography
- Table 1 – Main differences between IEC 60112 and ASTM D 3638
- Table A.1 – Applicability of test methods (1 of 2)
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes et définitions
- 4 Résumé des méthodes d'essai publiées [Go to Page]
- 4.1 Généralités
- 4.2 Essais utilisant l’air chauffé ou le chauffage électrique [Go to Page]
- 4.2.1 Détermination de la température d’allumage au moyen d’un four à air chaud, ISO 871
- 4.2.2 Analyse calorimétrique différentielle (Differential Scanning Calorimetry – DSC), ISO 11357 [1]
- 4.3 Essais utilisant la chaleur rayonnante [Go to Page]
- 4.3.1 Débit calorifique – Méthode au calorimètre à cône, ISO 5660-1 [4]
- 4.3.2 Dégagement de chaleur des liquides isolants, IEC TS 60695-8-3 [5]
- 4.3.3 Méthode d’essai normalisée pour la détermination des propriétés d’allumage des matériaux et de propagation de la flamme, ASTM E 1321 [6]
- 4.3.4 Détermination du flux de chaleur caractéristique pour l'allumage à partir d’une flamme source sans contact, IEC TS 60695-11-11 [7]
- 4.4 Essais d’indice d’oxygène [Go to Page]
- 4.4.1 Indice d’oxygène – Essai à la température ambiante, ISO 4589-2 [8]
- 4.4.2 Indice d’oxygène – Essai à haute température, ISO 4589-3 [10]
- 4.5 Méthodes d'essai au fil incandescent/chauffant [Go to Page]
- 4.5.1 Essais au fil incandescent, IEC 60695-2-11 [14], IEC 60695-2-12 [15] et IEC 60695-2-13 [16]
- 4.5.2 Essai d’allumabilité par bobine de fil chauffant, IEC 60695-2-20 et ASTM D 3874 [17]
- 4.6 Essais à la flamme [Go to Page]
- 4.6.1 Essai au brûleur-aiguille, IEC 60695-11-5 [18]
- 4.6.2 Méthodes d’essai horizontal et vertical à la flamme de 50 W, IEC 60695-11-10 [19] ; méthode d’essai à la flamme de 500 W, IEC 60695-11-20 [20]
- 4.6.3 Flamme à prémélange de 1 kW nominal, IEC 60695-11-2 [23]
- 4.6.4 Essai vertical et essai à 60( pour les composants aéronautiques, FAR 25 [25]
- 4.7 Essais utilisant un arc électrique [Go to Page]
- 4.7.1 Essais d’indice de cheminement, IEC 60112 [26], ASTM D 3638 [27]
- 4.7.2 Allumage par arc à courant élevé (High-Current Arc Ignition – HAI), UL 746A – Sec. 32 [30]
- 4.7.3 Résistance à l’allumage à arc à haute tension (High-Voltage Arc Resistance to Ignition – HVAR), UL 746A – Sec. 33 [31]
- Annexe A (informative) Applicabilité des méthodes d’essai [Go to Page]
- A.1 Applicabilité des méthodes d’essai
- Bibliographie
- Tableau 1 – Principales différences entre l’IEC 60112 et l’ASTM D 3638
- Tableau A.1 – Applicabilité des méthodes d’essai (1 de 2) [Go to Page]