IEC 62563-1 Ed. 1.1 b:2016 Medical electrical equipment - Medical image display systems - Part 1: Evaluation methods, 2016
- Redline version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, symbols and abbreviations [Go to Page]
- 3.1 Terms and definitions
- 3.2 Symbols
- 3.3 Abbreviations
- 4 General
- 5 Prerequisites
- 6 Equipment and tools [Go to Page]
- 6.1 Luminance meter
- 6.2 Illuminance meter
- 6.3 Colour meter
- 6.4 Test patterns
- 7 Evaluation methods [Go to Page]
- 7.1 General
- 7.2 Evaluation method table overview
- 7.3 Visual evaluation methods [Go to Page]
- 7.3.1 General
- 7.3.2 Overall image quality evaluation
- 7.3.3 Greyscale resolution evaluation
- 7.3.4 Luminance response evaluation
- 7.3.5 Luminance uniformity evaluation
- 7.3.6 Chromaticity evaluation
- 7.3.7 Pixel faults evaluation
- 7.3.8 Veiling glare evaluation
- 7.3.9 Geometrical image evaluation
- 7.3.10 Angular viewing evaluation
- 7.3.11 Clinical evaluation
- 7.4 Quantitative evaluation methods [Go to Page]
- 7.4.1 Basic luminance evaluation
- 7.4.2 Basic luminance evaluation without ambient light
- 7.4.3 Luminance response evaluation
- 7.4.4 Luminance evaluation of multiple displays
- 7.4.5 Chromaticity uniformity evaluation
- 7.4.6 Chromaticity evaluation across multiple displays
- 7.4.7 Luminance uniformity evaluation
- 7.4.8 Viewing angle evaluation
- 7.4.9 Greyscale chromaticity evaluation
- Annex A (informative) Sample test reports
- Annex B (informative) Luminance measurement methods
- Annex C (informative) Description of test patterns
- Bibliography
- Index of defined terms
- Figures [Go to Page]
- Figure 1 – Overall image quality evaluation using the TG18-QC test pattern
- Figure 2 – Overall image quality evaluation using the TG18-OIQ test pattern
- Figure 3 – Magnified view of TG18-MP test pattern showing the 8-bitand 10-bit markers
- Figure 4 – A close-up of the TG18-CT test pattern
- Figure 5 – The TG18-GV test pattern is displayed (left), a close-up of the centre of the test pattern when covered with a mask (right)
- Figure 6 – Geometrical evaluation using the GD pattern
- Figure 7 – Visual evaluation of viewing angle response
- Figure 8 – Example of the measured luminance in relation to the standard luminance response function according to greyscale standard display function (GSDF)
- Figure 9 – An example of the contrast response computed from 18 grey levels as related to the expected contrast response associated with the DICOM 3.14 [2] standard luminance response with a given tolerance limit (e.g. 15 %) [10]
- Figure B.1 – Method A, telescopic method
- Figure B.2 – Method B, near-range luminance meter in combination with an illuminance meter
- Figure B.3 – Method C, frontal integrated luminance meter in combination with illuminance meter
- Figure B.4 – Method D, back integrated luminance meter in combination with illuminance meter
- Figure C.1 – Example of TG-18 QC pattern for a matrix size of 1536 × 2048
- Tables [Go to Page]
- Table 1 – Overview to the definitions of physical parameters
- Table 2 – Test patterns used for display testing
- Table 3 – List of the evaluation methods that can be used for testing medical image display systems
- Table A.1 – Acceptance test sample report of a diagnostic display
- Table A.2 – Constancy test sample report of a diagnostic display
- Table A.3 – Acceptance test sample report of a monochrome reviewing display
- Table A.4 – Constancy test sample report of a monochrome reviewing display
- Table A.5 – Acceptance test sample report of a colour reviewing display
- Table A.6 – Constancy test sample report of a colour reviewing display
- Table C.1 – Description of multi-purpose test patterns
- Table C.2 – TG18-QC pattern: Luminance levels with 8-bit and [12-bit] pixel values and CX ratings
- Table C.3 – The blurring characteristics of the CX reference set utilized in TG18-QC test patterns [16]
- Table C.4 – Evaluation criteria for the examples of the clinical reference images
- Table C.5 – Example description of TG-18 QC pattern for a matrix size of 1536 × 2048
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l’Amendement 1
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes, définitions, symboles et abréviations [Go to Page]
- 3.1 Termes et définitions
- 3.2 Symboles
- 3.3 Abréviations
- 4 Généralités
- 5 Conditions préalables
- 6 Appareillage et outils [Go to Page]
- 6.1 luminance-mètre
- 6.2 Luxmètre
- 6.3 Colorimètre
- 6.4 Mires d’essai
- 7 Méthodes d’évaluation [Go to Page]
- 7.1 Généralités
- 7.2 Présentation générale du tableau descriptif des méthodes d’évaluation
- 7.3 Méthodes d’évaluation visuelle [Go to Page]
- 7.3.1 Généralités
- 7.3.2 Evaluation de la qualité globale de l’image
- 7.3.3 Evaluation de la résolution de l’échelle des gris
- 7.3.4 Evaluation de la réponse en luminance
- 7.3.5 Evaluation de l’uniformité de la luminance
- 7.3.6 Evaluation de la chromaticité
- 7.3.7 Evaluation des défauts de pixels
- 7.3.8 Evaluation du voile lumineux
- 7.3.9 Evaluation géométrique des images
- 7.3.10 Evaluation de l’observation angulaire
- 7.3.11 Evaluation clinique
- 7.4 Méthodes d’évaluation quantitative [Go to Page]
- 7.4.1 Evaluation de la luminance réduite
- 7.4.2 Evaluation de la luminance réduite sans lumière ambiante
- 7.4.3 Evaluation de la réponse en luminance
- 7.4.4 Evaluation de la luminance des affichages multiples
- 7.4.5 Evaluation de l'uniformité de la chromaticité
- 7.4.6 Evaluation de la chromaticité sur des affichages multiples
- 7.4.7 Evaluation de l’uniformité de la luminance
- 7.4.8 Evaluation de l’angle d’observation
- 7.4.9 Évaluation de la chromaticité de l'échelle des gris
- Annexe A (informative) Rapports d’essai échantillons
- Annexe B (informative) Méthodes de mesure de la luminance
- Annexe C (informative) Description des mires d’essai
- Bibliographie
- Index des termes définis
- Figures [Go to Page]
- Figure 1 – Evaluation de la qualité globale de l’image avec la mire d’essai TG18-QC
- Figure 2 – Evaluation de la qualité globale de l’image avec la mire d’essai TG18-OIQ
- Figure 3 – Vue agrandie de la mire d’essai TG18-MP présentant les marqueurs à 8 et 10 bits
- Figure 4 – Gros plan de la mire d’essai TG18-CT
- Figure 5 – Affichage de la mire d’essai TG18-GV (partie gauche), gros plan du centre de la mire d’essai recouverte d’un masque (partie droite)
- Figure 6 – Evaluation géométrique avec la mire GD
- Figure 7 – Evaluation visuelle de la réponse de l’angle d’observation
- Figure 8 – Exemple de luminance mesurée par rapport à la fonction de réponse en luminance normale selon la fonction d’affichage normal de l’échelle des gris (GSDF)
- Figure 9 – Exemple de la réponse en contraste calculée à partir de 18 niveaux de gris, par rapport à la réponse en contraste attendue associée à la réponse en luminance normale DICOM 3.14 [2], avec une limite de tolérance donnée (par exemple 15 %) [10]
- Figure B.1 – Méthode A, méthode télescopique
- Figure B.2 – Méthode B, luminance-mètre de portée proximale combiné à un luxmètre
- Figure B.3 – Méthode C, luminance–mètre intégré frontal combiné au luxmètre
- Figure B.4 – Méthode D, Luminance–mètre intégré arrière combiné au luxmètre
- Figure C.1 – Exemple de mire d’essai TG-18 QC pour une taille de matrice de 1536 × 2048
- Tableaux [Go to Page]
- Tableau 1 – Présentation générale des définitions des paramètres physiques
- Tableau 2 – Mires d’essai utilisées pour l’essai d’affichage
- Tableau 3 – Liste des méthodes d’évaluation pouvant être utilisées pour l’essai des systèmes d’imagerie médicale
- Tableau A.1 – Rapport-échantillon de l’essai d’acceptationd’un écran d’affichage de diagnostic
- Tableau A.2 – Rapport-échantillon de l’essai de constance d’un écran d’affichage de diagnostic
- Tableau A.3 – Rapport-échantillon de l’essai d’acceptation d’un écran d’affichage d’examen monochrome
- Tableau A.4 – Rapport-échantillon de l’essai de constance d’un écran d’affichage d’examen monochrome
- Tableau A.5 – Rapport-échantillon de l’essai d’acceptation d’un écran d’affichage d’examen couleur
- Tableau A.6 – Rapport-échantillon de l’essai de constance d’un écran d’affichage d’examen couleur
- Tableau C.1 – Description des mires d’essai polyvalentes
- Tableau C.2 – mire d’essai TG18-QC: Niveaux de luminance avec valeurs de pixelsà 8 bits et [12 bits] et caractéristiques assignées CX
- Tableau C.3 – Caractéristiques de flou de l’ensemble de référence CX utilisé dans les mires d’essai TG18-QC [16]
- Tableau C.4 – Critères d’évaluation pour les exemples des images cliniques de référence
- Tableau C.5 – Exemple de description de la mire d’essai TG-18 QC pour taille de matrice de 1536 × 2048
- Final version [Go to Page]
- English [Go to Page]
- CONTENTS
- FOREWORD
- INTRODUCTION
- INTRODUCTION to Amendment 1
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, symbols and abbreviations [Go to Page]
- 3.1 Terms and definitions
- 3.2 Symbols
- 3.3 Abbreviations
- 4 General
- 5 Prerequisites
- 6 Equipment and tools [Go to Page]
- 6.1 Luminance meter
- 6.2 Illuminance meter
- 6.3 Colour meter
- 6.4 Test patterns
- 7 Evaluation methods [Go to Page]
- 7.1 General
- 7.2 Evaluation method table overview
- 7.3 Visual evaluation methods [Go to Page]
- 7.3.1 General
- 7.3.2 Overall image quality evaluation
- 7.3.3 Greyscale resolution evaluation
- 7.3.4 Luminance response evaluation
- 7.3.5 Luminance uniformity evaluation
- 7.3.6 Chromaticity evaluation
- 7.3.7 Pixel faults evaluation
- 7.3.8 Veiling glare evaluation
- 7.3.9 Geometrical image evaluation
- 7.3.10 Angular viewing evaluation
- 7.3.11 Clinical evaluation
- 7.4 Quantitative evaluation methods [Go to Page]
- 7.4.1 Basic luminance evaluation
- 7.4.2 Basic luminance evaluation without ambient light
- 7.4.3 Luminance response evaluation
- 7.4.4 Luminance evaluation of multiple displays
- 7.4.5 Chromaticity uniformity evaluation
- 7.4.6 Chromaticity evaluation across multiple displays
- 7.4.7 Luminance uniformity evaluation
- 7.4.8 Viewing angle evaluation
- 7.4.9 Greyscale chromaticity evaluation
- Annex A (informative) Sample test reports
- Annex B (informative) Luminance measurement methods
- Annex C (informative) Description of test patterns
- Bibliography
- Index of defined terms
- Figures [Go to Page]
- Figure 1 – Overall image quality evaluation using the TG18-QC test pattern
- Figure 2 – Overall image quality evaluation using the TG18-OIQ test pattern
- Figure 3 – Magnified view of TG18-MP test pattern showing the 8-bitand 10-bit markers
- Figure 4 – A close-up of the TG18-CT test pattern
- Figure 5 – The TG18-GV test pattern is displayed (left), a close-up of the centre of the test pattern when covered with a mask (right)
- Figure 6 – Geometrical evaluation using the GD pattern
- Figure 7 – Visual evaluation of viewing angle response
- Figure 8 – Example of the measured luminance in relation to the standard luminance response function according to greyscale standard display function (GSDF)
- Figure 9 – An example of the contrast response computed from 18 grey levels as related to the expected contrast response associated with the DICOM 3.14 [2] standard luminance response with a given tolerance limit (e.g. 15 %) [10]
- Figure B.1 – Method A, telescopic method
- Figure B.2 – Method B, near-range luminance meter in combination with an illuminance meter
- Figure B.3 – Method C, frontal integrated luminance meter in combination with illuminance meter
- Figure B.4 – Method D, back integrated luminance meter in combination with illuminance meter
- Figure C.1 – Example of TG-18 QC pattern for a matrix size of 1536 × 2048
- Tables [Go to Page]
- Table 1 – Overview to the definitions of physical parameters
- Table 2 – Test patterns used for display testing
- Table 3 – List of the evaluation methods that can be used for testing medical image display systems
- Table A.1 – Acceptance test sample report of a diagnostic display
- Table A.2 – Constancy test sample report of a diagnostic display
- Table A.3 – Acceptance test sample report of a monochrome reviewing display
- Table A.4 – Constancy test sample report of a monochrome reviewing display
- Table A.5 – Acceptance test sample report of a colour reviewing display
- Table A.6 – Constancy test sample report of a colour reviewing display
- Table C.1 – Description of multi-purpose test patterns
- Table C.2 – TG18-QC pattern: Luminance levels with 8-bit and [12-bit] pixel values and CX ratings
- Table C.3 – The blurring characteristics of the CX reference set utilized in TG18-QC test patterns [16]
- Table C.4 – Evaluation criteria for the examples of the clinical reference images
- Table C.5 – Example description of TG-18 QC pattern for a matrix size of 1536 × 2048
- Français [Go to Page]
- SOMMAIRE
- AVANT-PROPOS
- INTRODUCTION
- INTRODUCTION à l’Amendement 1
- 1 Domaine d’application
- 2 Références normatives
- 3 Termes, définitions, symboles et abréviations [Go to Page]
- 3.1 Termes et définitions
- 3.2 Symboles
- 3.3 Abréviations
- 4 Généralités
- 5 Conditions préalables
- 6 Appareillage et outils [Go to Page]
- 6.1 luminance-mètre
- 6.2 Luxmètre
- 6.3 Colorimètre
- 6.4 Mires d’essai
- 7 Méthodes d’évaluation [Go to Page]
- 7.1 Généralités
- 7.2 Présentation générale du tableau descriptif des méthodes d’évaluation
- 7.3 Méthodes d’évaluation visuelle [Go to Page]
- 7.3.1 Généralités
- 7.3.2 Evaluation de la qualité globale de l’image
- 7.3.3 Evaluation de la résolution de l’échelle des gris
- 7.3.4 Evaluation de la réponse en luminance
- 7.3.5 Evaluation de l’uniformité de la luminance
- 7.3.6 Evaluation de la chromaticité
- 7.3.7 Evaluation des défauts de pixels
- 7.3.8 Evaluation du voile lumineux
- 7.3.9 Evaluation géométrique des images
- 7.3.10 Evaluation de l’observation angulaire
- 7.3.11 Evaluation clinique
- 7.4 Méthodes d’évaluation quantitative [Go to Page]
- 7.4.1 Evaluation de la luminance réduite
- 7.4.2 Evaluation de la luminance réduite sans lumière ambiante
- 7.4.3 Evaluation de la réponse en luminance
- 7.4.4 Evaluation de la luminance des affichages multiples
- 7.4.5 Evaluation de l'uniformité de la chromaticité
- 7.4.6 Evaluation de la chromaticité sur des affichages multiples
- 7.4.7 Evaluation de l’uniformité de la luminance
- 7.4.8 Evaluation de l’angle d’observation
- 7.4.9 Évaluation de la chromaticité de l'échelle des gris
- Annexe A (informative) Rapports d’essai échantillons
- Annexe B (informative) Méthodes de mesure de la luminance
- Annexe C (informative) Description des mires d’essai
- Bibliographie
- Index des termes définis
- Figures [Go to Page]
- Figure 1 – Evaluation de la qualité globale de l’image avec la mire d’essai TG18-QC
- Figure 2 – Evaluation de la qualité globale de l’image avec la mire d’essai TG18-OIQ
- Figure 3 – Vue agrandie de la mire d’essai TG18-MP présentant les marqueurs à 8 et 10 bits
- Figure 4 – Gros plan de la mire d’essai TG18-CT
- Figure 5 – Affichage de la mire d’essai TG18-GV (partie gauche), gros plan du centre de la mire d’essai recouverte d’un masque (partie droite)
- Figure 6 – Evaluation géométrique avec la mire GD
- Figure 7 – Evaluation visuelle de la réponse de l’angle d’observation
- Figure 8 – Exemple de luminance mesurée par rapport à la fonction de réponse en luminance normale selon la fonction d’affichage normal de l’échelle des gris (GSDF)
- Figure 9 – Exemple de la réponse en contraste calculée à partir de 18 niveaux de gris, par rapport à la réponse en contraste attendue associée à la réponse en luminance normale DICOM 3.14 [2], avec une limite de tolérance donnée (par exemple 15 %) [10]
- Figure B.1 – Méthode A, méthode télescopique
- Figure B.2 – Méthode B, luminance-mètre de portée proximale combiné à un luxmètre
- Figure B.3 – Méthode C, luminance–mètre intégré frontal combiné au luxmètre
- Figure B.4 – Méthode D, Luminance–mètre intégré arrière combiné au luxmètre
- Figure C.1 – Exemple de mire d’essai TG-18 QC pour une taille de matrice de 1536 × 2048
- Tableaux [Go to Page]
- Tableau 1 – Présentation générale des définitions des paramètres physiques
- Tableau 2 – Mires d’essai utilisées pour l’essai d’affichage
- Tableau 3 – Liste des méthodes d’évaluation pouvant être utilisées pour l’essai des systèmes d’imagerie médicale
- Tableau A.1 – Rapport-échantillon de l’essai d’acceptation d’un écran d’affichage de diagnostic
- Tableau A.2 – Rapport-échantillon de l’essai de constance d’un écran d’affichage de diagnostic
- Tableau A.3 – Rapport-échantillon de l’essai d’acceptation d’un écran d’affichage d’examen monochrome
- Tableau A.4 – Rapport-échantillon de l’essai de constance d’un écran d’affichage d’examen monochrome
- Tableau A.5 – Rapport-échantillon de l’essai d’acceptation d’un écran d’affichage d’examen couleur
- Tableau A.6 – Rapport-échantillon de l’essai de constance d’un écran d’affichage d’examen couleur
- Tableau C.1 – Description des mires d’essai polyvalentes
- Tableau C.2 – mire d’essai TG18-QC: Niveaux de luminance avec valeurs de pixels à 8 bits et [12 bits] et caractéristiques assignées CX
- Tableau C.3 – Caractéristiques de flou de l’ensemble de référence CX utilisé dans les mires d’essai TG18-QC [16]
- Tableau C.4 – Critères d’évaluation pour les exemples des images cliniques de référence
- Tableau C.5 – Exemple de description de la mire d’essai TG-18 QC pour taille de matrice de 1536 × 2048 [Go to Page]